Приказ основних података о документу
Analysis of accuracy and precision of optical 3D digitisation devices in dental computer-aided-design and computer-aided-manufacturing systems
dc.creator | Trifković, Branka | |
dc.creator | Budak, Igor | |
dc.creator | Vukelić, Đorđe | |
dc.creator | Puškar, Tatjana | |
dc.creator | Jevremović, Danimir | |
dc.creator | Todorović, Aleksandar | |
dc.creator | Todorović, Ana | |
dc.creator | Poštić, Srđan | |
dc.date.accessioned | 2020-07-02T13:13:40Z | |
dc.date.available | 2020-07-02T13:13:40Z | |
dc.date.issued | 2017 | |
dc.identifier.issn | 1905-7873 | |
dc.identifier.uri | https://smile.stomf.bg.ac.rs/handle/123456789/2257 | |
dc.description.abstract | The implementation of intraoral and extraoral computer-aided-design and computer-aided-manufacturing (CAD/CAM) systems in prosthetic dentistry has simplified the procedure, shortened the period of design and manufacture and improved accuracy and aesthetic properties of dental restorations. Three-dimensional (3D) digitisation has become an adequate replacement for conventional dental impressions. The market offers a variety of diverse optical intraoral and extraoral CAD/CAM systems equipped with digitisation devices that are based on different working principles. The main goal of this research is to determine whether precision and accuracy differ among optical digitisation devices. The research includes five high-end devices: Cerec AC, Cerec InEos, Trios, KaVo Everest and Sinergia Scan. The evaluation methodology of the experiment is based on CAD inspection. The results, obtained from accuracy and precision measurements with tolerance levels of 0.01, 0.25 and 0.05 mm, indicate that there is a difference in accuracy and precision between optical digitisation devices based on different working principles. | en |
dc.publisher | Maejo University | |
dc.relation | Ministry of Education, Science and Technological Development of the Republic of Serbia | |
dc.rights | openAccess | |
dc.rights.uri | https://creativecommons.org/licenses/by-nc/4.0/ | |
dc.source | Maejo International Journal of Science & Technology | |
dc.subject | computer-aided design | en |
dc.subject | computer-aided manufacturing | en |
dc.subject | 3D digitisation | en |
dc.subject | dental technology | en |
dc.subject | dental equipment | en |
dc.title | Analysis of accuracy and precision of optical 3D digitisation devices in dental computer-aided-design and computer-aided-manufacturing systems | en |
dc.type | article | |
dc.rights.license | BY-NC | |
dcterms.abstract | Вукелић, Ђорђе; Пушкар, Татјана; Поштић, Срђан; Трифковић, Бранка; Будак, Игор; Јевремовић, Данимир; Тодоровић, Aлександар; Тодоровић, Aна; | |
dc.citation.volume | 11 | |
dc.citation.issue | 1 | |
dc.citation.spage | 45 | |
dc.citation.epage | 57 | |
dc.citation.other | 11(1): 45-57 | |
dc.citation.rank | M23 | |
dc.identifier.wos | 000396726900007 | |
dc.identifier.scopus | 2-s2.0-85016147035 | |
dc.identifier.fulltext | https://smile.stomf.bg.ac.rs/bitstream/id/5157/Analysis_of_accuracy_pub_2017.pdf | |
dc.identifier.rcub | https://hdl.handle.net/21.15107/rcub_smile_2257 | |
dc.type.version | publishedVersion |